ECHOTROL™ Rigid ACOUSTIC Baffles

ECHOTROL™ ACOUSTIC RIGID BAFFLES offer excellent sound absorption characteristics in a number of cost-effective architectural finishes. These attributes enable them to be utilized in virtually any interior environment requiring sound quality improvements. Each panel consists of rigid high-density and formaldehyde-free acoustical fiberglass. Finishes include fire-rated acoustical fabrics in a variety of colors and textures.

Baffles in varying in sizes and colours may also be combined for an interesting abstract appearance.

Echotrol™ Rigid Acoustic Baffles: The Sound Solution for Modern Spaces

In today's architectural landscape, the need for effective sound control is paramount. Echotrol™ Rigid Acoustic Baffles by Western Noise Control are meticulously engineered to meet this demand.

Key Features of Echotrol™ Rigid Acoustic Baffles:

  • Exceptional Sound Absorption: Crafted with high-density, formaldehyde-free acoustical fiberglass, these baffles ensure optimal noise control, creating serene spaces.

  • Stylish Architectural Finishes: Available in a range of fire-rated acoustical fabrics, colors, and textures, these baffles are designed to complement any interior decor.

  • Versatile Design: Whether you're aiming for a minimalist look or an abstract design, the varying sizes and colors of our baffles allow for creative installations.

  • Safety Standards: Meeting multiple flammability standards, our baffles ensure safety without compromising on design or functionality.

Echotrol™ Rigid Acoustic Baffles are more than just sound barriers; they are a testament to innovative design, safety, and acoustic engineering. Transform your space with the best in sound control and design aesthetics.

  • Ceiling

    Different mounting hardware will be used depending on the installation location and ceiling type. Baffles may be directly mounted to the ceiling on with eye screws, or suspended using a cable system. Contact us to discuss your specific project.

  • Education Sector: Libraries, Learning Commons, Break Out Rooms, Auditoriums, Hallways, Corridors, Music Rooms, Cafeterias, Etc.

    Office/Workplace Sector: Offices, Boardrooms, Lunch Rooms, Meeting Rooms, Open Office Areas, Etc.

    Entertainment Sector: Theatres, Movie Theatres, Recording Studios, Performance Spaces, Community Halls, Bars & Restaurants, Etc.

    Places of Worship: Churches, Mosques, Retreat Centres, Synagogues, Fellowship Halls, Etc.

  • In construction specifications, the organization is structured into divisions that outline requirements for various construction elements. Division 9 is specifically dedicated to "Finishes." Within Division 9, you can find specifications related to different finishing materials and methods, such as painting, plastering, and flooring.

    Acoustic baffles, being integral to interior sound control, would typically be located under Division 9. More specifically, they might be situated under a subsection dedicated to "Acoustical Treatments" or "Acoustical Ceiling and Wall Treatments." The exact section number or title might differ based on the specific format or version of the specification in use, but it's common to find them under a title like "09 81 00 - Acoustical Baffle Treatments" or a similar designation.

    Within this section or subsection, you would encounter detailed specifications for the acoustic baffles, including material descriptions, installation guidelines, performance criteria, and other pertinent details.

    If you're navigating a specific set of construction specifications or a distinct format, it's always advisable to refer to the table of contents or index to pinpoint the exact section detailing acoustic baffles.

DOWNLOADS:

Brochure

Specification

Acoustical Performance

NRC RATING

NOISE REDUCTION COEFFICENT

Noise Reduction Coefficient (NRC) is calculated by averaging the sound absorption coefficients of a material at four frequencies (250 Hz, 500 Hz, 1000 Hz, and 2000 Hz) as measured in a reverberation room according to ASTM C423 standards.

Echotrol NRC Data - Panels 2
Frequency (Hz)


125
250
500
1000
2000
4000
NRC
50mm
ASTM*
0.29
0.98
1.09
0.96
1.01
0.97
1.00
50mm Industry** 0.58
1.96 2.18 1.92
2.02
1.94
2.02
*ASTM Reporting Protocol Reports 
**Common Industry Reporting Protocol That Adds the Absorption From Both Sides of the Baffle Together

fire rating/flammability

Flammability

ASTM E-84

Class 1 or A

NFPA-701

Passes

Boston Fire Code BFD 1X-1

Passes

State of Ca. CS-191-53

Passes

GSA-PBS

Passes

UL Test #214

Passes

CAN / ULC - S102

Passes


Fire Rating

Edge:

  • MDF Hard Edge Profile

  • Western Noise Control Does Not Use Resin for Hard Edge. This reduces VOCs and reduces the probability of cracking due to repeated impact.

Size & shape Options

  • Panels are available in configurations within a 4’x8’ grid. (1220mm x 2400mm)

  • Echotrol™ SHAPES options are also available. This includes but is not limited to triangles, trapezoids, circles, and hexagons.

fabric Options